Data CentresGoogle Data Centre
Sequence of operations, insulation coordination, transformer energisation, relay coordination and arc-flash study for a hyperscale campus.
48 delivered scopes across data centres, renewables, energy storage, transmission substations and heavy industry.
Our studies have been accepted by transmission operators and hyperscale developers in India, the United Kingdom, Malaysia and Africa — from Google, Amazon and Microsoft data centres to NTPC grid-scale storage and PGCIL transmission. The highlighted countries mark where NEWATT has delivered.

Data CentresSequence of operations, insulation coordination, transformer energisation, relay coordination and arc-flash study for a hyperscale campus.
Data CentresLoad flow, voltage drop, fault level, reactive-power and relay-coordination studies.
Data CentresInsulation coordination, earthing-grid design, load flow / short circuit, relay coordination and arc-flash study.
Data CentresLoad flow / short circuit, protection coordination and arc-flash study.
Data CentresSequence of operations, insulation coordination and transformer-energisation study.
Data CentresLoad flow, short circuit, ENA P28 voltage-fluctuation, P29 unbalance, harmonics and protection studies to UK grid code.
Data CentresSequence of operations, insulation coordination, transformer energisation, relay coordination and arc-flash study.
Data CentresRelay coordination study.
Data CentresLoad flow / short circuit at 132 / 13.8 kV, relay coordination up to 13.8 kV and arc-flash to IEEE 1584.
Data CentresLoad flow, voltage drop, fault level, reactive-power and relay-coordination studies.
Renewable Energy275 kV substation ETAP model, protection settings, TCC analysis and PV inverter, CB, CT and VT modelling.
Renewable EnergyETAP IEC short-circuit study, maximum and minimum faults, withstand verification and peak-current assessment.
Renewable EnergyLoad flow, short circuit and relay coordination.
Renewable EnergyLoad flow, short circuit and relay coordination for one of the largest hybrid plants in the Bikaner cluster.
Renewable EnergyLoad flow, short circuit and relay coordination.
Renewable EnergyRelay coordination study for a hybrid renewable plant.
Renewable EnergyGrid compliance study to state transmission utility requirements.
Renewable EnergyLoad flow, short circuit and relay coordination.
Renewable EnergyGrid compliance study to state transmission utility requirements.
Renewable EnergyGrid compliance study — reactive capability, ride-through and protection.
Renewable EnergyLoad flow, short circuit, relay coordination and arc flash.
Renewable EnergyRelay coordination and 400 kV bay protection settings.
Energy Storage (BESS)Design consultancy for a utility-scale grid-connected BESS — electrical, civil and structural detailed engineering.
Energy Storage (BESS)Full power system studies and electrical detailed design: load flow, short circuit, dynamic stability, LVRT/HVRT, frequency response, reactive-power validation, relay coordination, power quality, harmonics, PSS/E and PSCAD simulations, SLD, equipment sizing, cable and panel design.
Energy Storage (BESS)Design consultancy for a utility-scale grid-connected BESS — electrical, civil and structural detailed engineering.
Substation Detailed EngineeringDetailed engineering — electrical.
Substation Detailed EngineeringDetailed engineering — electrical, civil and structural.
Substation Detailed EngineeringDetailed engineering — electrical, civil and structural.
Substation Detailed EngineeringDetailed engineering — electrical, civil and structural.
Substation Detailed EngineeringDetailed engineering — civil and structural.
Substation Detailed EngineeringDetailed engineering — civil and structural.
Substation Detailed EngineeringDetailed engineering — electrical.
Substation Detailed EngineeringDetailed engineering — electrical, civil and structural.
Substation Detailed EngineeringDetailed engineering — electrical, civil and structural.
Thermal, Industrial & Co-generationLoad flow, short circuit, relay coordination and motor starting for the FGD system.
Thermal, Industrial & Co-generationLoad flow and protection coordination for the FGD system.
Thermal, Industrial & Co-generationDesign engineering, load flow, short circuit and protection coordination.
Thermal, Industrial & Co-generationLoad flow, short circuit, protection coordination, voltage drop and motor starting.
Thermal, Industrial & Co-generationLoad flow, short circuit and protection coordination.
Thermal, Industrial & Co-generationLoad flow, short circuit, protection with generators, arc flash, harmonics, voltage stability, power quality, grid code, lightning risk and step/touch earthing.
Thermal, Industrial & Co-generationElectrical design engineering, load flow, short circuit, protection coordination and arc flash.
Transmission & Cable EngineeringCable schedule preparation for Power Grid Corporation of India transmission projects.
Transmission & Cable EngineeringCable schedule preparation for Power Grid Corporation of India transmission projects.
Transmission & Cable EngineeringCable schedule preparation for Power Grid Corporation of India transmission projects.
Transmission & Cable EngineeringCable schedule preparation for Power Grid Corporation of India transmission projects.
We can share sanitised report extracts and, where the client permits, direct references for comparable projects.